OCLEG Electronics

Section 3

THREE PHASE DOL MOTOR STARTER

3.1

DOL STARTER (MK-1 TYPE)

Specification

  • MK-1 type Contactor & Thermal Relay
  • Thermal Overload Protection
  • Powder Coated Sheet Metal Enclosure
SR NO.H.P.RELAY RANGECONTACTOR TYPE
13.06-10 AMK-1
25.09-14 AMK-1
37.513-21 AMK-1
47.5 (Heavy)13-21 A (DMC)MK-1
510.0 (Heavy)20-32 A (DMC)MK-1

Application

Induction Motor, Three Phase Dol Monoblock/ Openwell Pump Set For Drawing Water in Residence, Commercial, Farming, Gardening Purpose.

DOL STARTER (MK-1 TYPE)

3.2

OTW (ELECTRONIC TYPE)

Specification

  • Electronic Start/Stop Push Button
  • Accurate overload Protection
  • With Dry Run Protection (Optional) Model OTW-D
  • Extreme High Voltage Protection
  • Phase Failure Protection (SPP)
  • Reverse Phasing & Unbalance Voltage Protection
  • "Auto / Manual" Mode Selector Switch (Optional) Model OTA
  • Auto Start Facility Provided with starting time delay
  • Engineering Grade Plastic Enclosure
  • Can Be Used Up to 7.5 Hp DOL Motor/Pumps.
SR NO.H.P.RELAY RANGE
13.04-10 A
25.08-20 A
37.58-20 A

Application

Induction Motor, Three Phase Dol Monoblock/ Openwell Pump Set For Drawing Water in Residence, Commercial, Farming, Gardening Purpose.

OTW (ELECTRONIC TYPE)

3.3

ODP-306 (DIGITAL TYPE)

Specification

  • Digital Volt-Current Meter with C.T
  • Accurate overload Protection
  • With Dry Run Protection (Optional)
  • Extreme High Voltage Protection
  • Phase Failure Protection (SPP)
  • Reverse Phasing & Unbalance Voltage Protection
  • "Auto / Manual" Mode Selector Switch
  • Auto Start Facility Provided with starting time delay
  • Set Over Load / Dry run Automatically by Pressing only "SET" key ("Auto-Set" System)
  • Inbuilt "CYCLIC TIMER / OFF TIMER" Facility (Optional)
SR NO.H.P.RELAY RANGE
13.02-25 A
25.02-25 A
37.52-25 A

Application

Induction Motor, Three Phase Dol Monoblock/ Openwell Pump Set For Drawing Water in Residence, Commercial, Farming, Gardening Purpose.

ODP-306 (DIGITAL TYPE)

3.4

ODP-306-LLC (With Automatic Water Level Controller)

Specification

  • Digital Volt-Current Meter with C.T
  • Accurate overload Protection
  • With Dry Run Protection (Optional)
  • Extreme High Voltage Protection
  • Phase Failure Protection (SPP)
  • Reverse Phasing & Unbalance Voltage Protection
  • Set Over Load / Dry run Automatically by Pressing only "SET" key ("Auto-Set" System)
  • Inbuilt Automatic Water Level Controller Facility
SR NO.H.P.RELAY RANGE
13.02-25 A
25.02-25 A
37.52-25 A

Application

Induction Motor, Three Phase Dol Monoblock/ Openwell Pump Set For Drawing Water in Residence, Commercial, Farming, Gardening Purpose.

ODP-306-LLC (With Automatic Water Level Controller)
ODP-306-LLC (With Automatic Water Level Controller)